Error codes
Victron inverter error codes
Victron equipment shows numbered errors in the VictronConnect app, on a GX display or in VRM. MPPT solar chargers use "Err" numbers; Multi and Quattro inverter-chargers use VE.Bus error numbers. On an off-grid system, the first safe check is the battery state of charge.
By Scott Charles, Bolido Solar
Updated
MPPT charger: battery errors
An MPPT charger is the device that takes power from the panels and charges the batteries.
Err 1Battery temperature too high
Charging has stopped to protect a hot battery. It resets once the battery cools.
- Safe to reset?
- Safe to restart
- When to call an engineer
- Call us if it happens often; the battery location may need ventilation.
Err 2Battery voltage too high
The battery voltage is above the charger setting, often because another charger is pushing it up or a setting is wrong.
- Safe to reset?
- Check first
- When to call an engineer
- Call us to check the settings across all chargers on the system.
Err 11High battery ripple voltage
Usually loose or undersized DC cabling between charger and battery.
- Safe to reset?
- Leave it, call an engineer
- When to call an engineer
- Call an engineer. Ripple shortens the life of the equipment.
Err 14Battery temperature too low
Charging has stopped to protect lithium batteries in the cold.
- Safe to reset?
- Safe to restart
- When to call an engineer
- It resumes as the battery warms. Call us if the battery is somewhere that regularly freezes.
Err 29Over-charge protection
The battery has been disconnected from charging because its voltage is too high.
- Safe to reset?
- Check first
- When to call an engineer
- Call us if it repeats. Causes include too many panels in series or mismatched settings.
Err 67BMS connection lost
The charger is set to follow the battery management system (BMS) and has stopped hearing from it, so it stops charging.
- Safe to reset?
- Check first
- When to call an engineer
- Check the battery is switched on. If it is, call an engineer.
MPPT charger: charger and panel errors
Err 17Charger overheated
The charger got too hot even after reducing its output. It resets when it cools.
- Safe to reset?
- Check first
- When to call an engineer
- Make sure nothing blocks its heat sink and the space is ventilated.
Err 18Charger over-current
Too much current on the battery side, often from a large load switching on or a sudden change in sunlight.
- Safe to reset?
- Check first
- When to call an engineer
- If it does not clear itself, call us.
Err 26Terminal overheated
A cable terminal is too hot, usually because a connection is loose.
- Safe to reset?
- Leave it, call an engineer
- When to call an engineer
- Call an engineer. Loose DC terminals are a fire risk.
Err 33PV over-voltage
The voltage from the panels is above the charger’s limit.
- Safe to reset?
- Leave it, call an engineer
- When to call an engineer
- Call an engineer. The panel layout needs reconfiguring.
Err 34PV over-current
Too much current from the panels, possibly an internal fault.
- Safe to reset?
- Check first
- When to call an engineer
- If it persists, call us.
Err 38, 39PV input shutdown
The charger has shut its panel input to protect the battery from over-charging, often because of a battery voltage setting or another charger.
- Safe to reset?
- Check first
- When to call an engineer
- Call us to check the battery voltage setting and other chargers on the system.
Err 41, 42Isolation or ground fault
Low insulation resistance on the panel side, or current leaking to earth.
- Safe to reset?
- Leave it, call an engineer
- When to call an engineer
- Book an engineer to test the cabling and panels.
Err 116, 119Calibration or settings data lost
The charger has lost its calibration (116) or settings (119).
- Safe to reset?
- Leave it, call an engineer
- When to call an engineer
- Call an engineer. 119 needs a reset and reconfiguration; an active 116 usually means replacement.
Multi and Quattro (VE.Bus) errors
VE.Bus 1A phase has switched off
One unit has switched off, often because of a low battery, overload or high temperature; the others show this code.
- Safe to reset?
- Check first
- When to call an engineer
- Find the unit not showing the code and check its lights. Call us if the cause is not obvious.
VE.Bus 3Devices missing
The system did not find the number of units it expects, often after Error 1 or because of a communication cable fault.
- Safe to reset?
- Leave it, call an engineer
- When to call an engineer
- Call an engineer.
VE.Bus 5Overvoltage on AC out
AC wiring on one of the units is incorrect or missing.
- Safe to reset?
- Leave it, call an engineer
- When to call an engineer
- Call an engineer.
VE.Bus 8Ground relay test failed
The internal earth relay failed its self-test.
- Safe to reset?
- Leave it, call an engineer
- When to call an engineer
- Call an engineer.
Written in our own words from the manufacturer’s documentation. For the full list, see Victron MPPT error codes.
Victron questions
What does Err 38 mean on a Victron MPPT?
The charger has shut down its panel input to protect the battery from over-charging, often because the battery voltage setting is wrong or another charger is raising the voltage. It needs the settings checking.
What does Err 2 mean on a Victron charger?
Battery voltage too high. Usually another charger on the system is pushing the voltage up, or the charger settings do not match the battery.
What does VE.Bus Error 1 mean?
One unit in a multi-unit system has switched off, and the others report Error 1. Find the unit without the code and check its lights to see why.