Skip to content
Bolido Solar

Error codes

Solis inverter error codes

Solis inverters show a short alarm name on the screen and in the SolisCloud app, such as NO-Grid or OV-G-V. The first safe check is whether the house has power and the solar breaker in your fuse box is on.

By Scott Charles, Bolido Solar
Updated

Grid alarms

NO-GridNo grid detected

The inverter cannot see grid voltage at all.

Safe to reset?
Check first
When to call an engineer
Check the solar breaker and AC isolator. If both are on and the house has power, call an engineer.

OV-G-VGrid voltage too high

The grid voltage at your connection went above the limit.

Safe to reset?
Safe to restart
When to call an engineer
If it repeats on sunny days, ask your DNO to check the supply. Undersized cable to the inverter can also cause it.

UN-G-VGrid voltage too low

The grid voltage dropped below the limit.

Safe to reset?
Safe to restart
When to call an engineer
Call us if it persists while the house has power.

OV-G-F, UN-G-FGrid frequency too high or too low

The grid frequency went outside the permitted range.

Safe to reset?
Safe to restart
When to call an engineer
Call us if it appears often.

GRID-INTFGrid interference

The inverter detected unstable grid conditions or a high internal fault current.

Safe to reset?
Check first
When to call an engineer
Restart once at the isolators. If it returns, call an engineer.

G-IMPHigh grid impedance

The grid connection is weaker than the inverter expects.

Safe to reset?
Check first
When to call an engineer
Call us. Protection settings can only be changed with the DNO agreeing.

LimByVgPower limited by grid voltage

Output is being reduced because the grid voltage is high.

Safe to reset?
Safe to restart
When to call an engineer
If it is frequent, raise the grid voltage with your DNO.

Panels and DC side

OV-DCDC voltage too high

The voltage from the panels is too high, usually too many panels on one string.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Switch off the DC isolator and call an engineer.

PV ISO-PRO 01/02Insulation fault

Low insulation resistance on a panel string: a leak to earth, usually water in a connector or damaged cable.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Book an engineer. Note the weather when it appears; it helps the test.

ILeak-PRO 01–04Leakage current

Current is leaking to earth on the AC or DC side.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Book an engineer.

ARC-FaultArc detected

The inverter detected arcing in the DC circuit, a fire risk.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Switch off the DC and AC isolators and call an engineer straight away.

AFCI Check FAULTArc detector self-check failed

The arc detection module failed its own check.

Safe to reset?
Check first
When to call an engineer
Restart once at the isolators. If it returns, call an engineer.

Inverter alarms

OV-TEMOver temperature

The inverter shut down because it got too hot.

Safe to reset?
Check first
When to call an engineer
Make sure the heat sink and vents are clear and it is out of direct sun. Call if it repeats.

Fan-FailFan not running

One or more cooling fans has stopped.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer before it overheats.

OV-BUS, UN-BUSInternal DC voltage out of range

The voltage inside the inverter is too high or too low.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer.

INI-FAULTStart-up check failed

The inverter failed its start-up checks.

Safe to reset?
Check first
When to call an engineer
Restart once. If it persists, the inverter likely needs replacing.

Relay-FaultRelay check failed

The relay that connects the inverter to the grid failed its check.

Safe to reset?
Check first
When to call an engineer
Restart once. If it returns, call an engineer.

DCinj-FaultHigh DC injection

Too much DC current detected on the AC output.

Safe to reset?
Check first
When to call an engineer
Restart once. If it returns, call an engineer.

Battery and hybrid alarms

These appear on hybrid models with a battery attached.

NO-BatteryBattery not detected

The inverter cannot see the battery.

Safe to reset?
Check first
When to call an engineer
Check the battery is switched on at its own switch or breaker. If it is, call an engineer.

BAT_Comm-FAIL, CAN_Comm_FAILBattery communication failure

The inverter and battery have stopped talking to each other, or the wrong battery type is selected.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer to check the communication cable and settings.

Alarm-BMSBattery management alarm

The battery management system (BMS), the battery’s own controller, has raised an alarm.

Safe to reset?
Check first
When to call an engineer
Restart the battery as its manual describes. If it persists, call us.

OV-Vbatt, UN-VbattBattery voltage out of range

The battery voltage is above or below the settings, sometimes a sign of a battery near the end of its life.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer to check the settings and the battery.

MET_Comm-FAILMeter communication failure

The inverter cannot read its energy meter.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer to check the meter wiring.

Written in our own words from the manufacturer’s documentation. For the full list, see Solis documentation.

Solis questions

What does NO-Grid mean on a Solis inverter?

The inverter cannot detect the grid. Check the solar breaker in your fuse box and the AC isolator first. If both are on and the house has power, the fault needs an engineer.

What does OV-G-V mean on a Solis inverter?

Grid voltage too high. The inverter disconnects to stay within the rules and reconnects when the voltage drops. If it happens most sunny days, raise it with your DNO.

What does PV ISO-PRO mean on Solis?

An insulation fault on a panel string: a leak to earth, usually from water in a connector or a damaged cable. It needs an engineer to test the array.

Get a free solar quote

Need a new inverter, a battery or a full upgrade? Tell us about your home. For a Solis fault, use Report a fault instead.

or call 0330 345 3400