Fronius inverter error codes

Fronius inverters show a STATE number on the display and in Solar.web, such as STATE 306. Some are normal at dawn and dusk. The first safe check is whether the house has power and the solar breaker in your fuse box is on.

By Scott Charles, Bolido Solar
Updated

Grid conditions

The grid was outside the permitted range, so the inverter stopped feeding in. It restarts on its own when conditions return to normal.

102AC voltage too high

The grid voltage went above the limit.

Safe to reset?
Safe to restart
When to call an engineer
If it repeats on sunny days, ask your DNO to check your supply voltage, then call us.

103AC voltage too low

The grid voltage dropped below the limit.

Safe to reset?
Safe to restart
When to call an engineer
If it persists while the house has power, call an engineer.

105, 106AC frequency too high or too low

The grid frequency went outside the permitted range.

Safe to reset?
Safe to restart
When to call an engineer
Call us if it appears often.

107Grid outside permitted limits

The inverter cannot see a grid within its limits, which includes no grid at all.

Safe to reset?
Check first
When to call an engineer
Check the solar breaker and AC isolator. If both are on, call an engineer.

108Stand-alone operation detected

The inverter saw signs of the grid being cut off and disconnected as a safety measure.

Safe to reset?
Safe to restart
When to call an engineer
Call us if it happens without a power cut.

567Power reduced: high grid voltage

Output is being reduced because the grid voltage went above 250V.

Safe to reset?
Safe to restart
When to call an engineer
If it recurs, raise the grid voltage with your DNO.

Panels and DC side

306PV output too low

Not enough power from the panels to feed into the grid. Normal at dawn and dusk.

Safe to reset?
Safe to restart
When to call an engineer
Only a concern if it appears in full sunlight.

307Low PV voltage

The voltage from the panels is too low to feed in. Normal at dawn and dusk.

Safe to reset?
Safe to restart
When to call an engineer
Only a concern in good light.

309, 313DC input voltage too high

The voltage on one of the panel inputs (MPPT 1 or 2) is above the limit. MPPT is the tracker that gets the most power from each set of panels.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Switch off the DC isolator and call an engineer.

311DC strings reversed

The polarity of the panel strings is the wrong way round.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer.

447, 475Insulation fault

A leak to earth on the panel side, usually water in a connector or damaged cable.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Book an engineer to test the array.

502Insulation warning

A warning that insulation on the panel side is lower than it should be. The inverter may keep running.

Safe to reset?
Check first
When to call an engineer
If it recurs, book an engineer before it becomes a fault.

522, 523DC low on string 1 or 2

One string of panels is producing little or nothing while the other works.

Safe to reset?
Check first
When to call an engineer
Look for new shading on that part of the roof. If there is none, call us to test the string.

Inverter faults and warnings

301AC overcurrent

A brief interruption caused by too much current on the AC side, followed by an automatic restart.

Safe to reset?
Safe to restart
When to call an engineer
If it is constant, call an engineer.

303, 304Module over temperature

Part of the inverter got too hot, so it paused.

Safe to reset?
Check first
When to call an engineer
Make sure the vents and heat sink are not blocked. Call if it recurs.

517Power reduced: temperature

Output reduced because the inverter is too warm.

Safe to reset?
Safe to restart
When to call an engineer
If it happens often, the location needs better ventilation.

401, 416No communication with the power stage

Internal parts of the inverter stopped talking to each other. It usually reconnects on its own.

Safe to reset?
Safe to restart
When to call an engineer
If it is constant, call an engineer.

431Software problem

The inverter has stopped feeding in because of a software fault.

Safe to reset?
Check first
When to call an engineer
Switch the AC breaker off and on once. If it returns, it needs a firmware update or service from an engineer.

457Grid relay sticking

The relay that connects to the grid is sticking, or the neutral-to-earth voltage is too high.

Safe to reset?
Leave it, call an engineer
When to call an engineer
Call an engineer.

509No energy fed in for 24 hours

Nothing has been fed into the grid in the past day.

Safe to reset?
Check first
When to call an engineer
Look for other codes on the display. If there are none and the weather was reasonable, call us.

Written in our own words from the manufacturer’s documentation. For the full list, see Fronius UK service and support.

Fronius questions

What does Fronius STATE 306 mean?

The panels are not producing enough power to feed into the grid. It is normal at dawn and dusk. If it shows in full sunlight, something is wrong and it is worth a call.

What does Fronius STATE 509 mean?

No energy has been fed into the grid in the past 24 hours. It is a summary rather than a cause, so look for any other code on the display.

What does Fronius STATE 447 mean?

An insulation fault: a leak to earth on the panel side, usually from water in a connector or a damaged cable. It needs an engineer to test the array.